SCHEDULE B2
BUSINESS CONTINUITY
Version History
Version No. Date Comments
1.0 31/08/06 Agreed version as at date of signature of CCN 1200
6.0 15/06/09 Moving all schedules to V6.0 as agreed with Fujitsu
6.1 31/03/10 Applying changes as per CCN1276a
7.0 10/05/10 Moving all schedules to V7.0 as agreed with Fujitsu
8.0 21/02/12 Moving all schedules to v8.0 in accordance with CCN1294d
9.0 13/01/14 Moving all Schedules to v9.0 in accordance with CCN1349
10.0 10/09/15 CCD Update and moving all Schedules to v10.0 in
accordance with CCN1506
11.0 31/03/16 Applying changes as per CCN1423c and moving all
Schedules to V11.0 in accordance with CCN1604
12.0 03/07/17 Applying changes as per CCN 1610 and moving all
schedules to V12.0
13.0 Updating as per CCN1616b, CCN1617a and moving all
Schedules to v13.0
Schedule B2 Version 13.0
Page 1 of 4
CONFIDENTIAL
SCHEDULE B2
BUSINESS CONTINUITY
1. GENERAL
1.1 Fujitsu Services shall ensure that the Applicable Services are supported by Business
Continuity Plans. Where requested by Post Office and agreed by Fujitsu Services (such
agreement not to be unreasonably withheld) Fujitsu Services shall ensure that new
services are supported by Business Continuity Plans.
Fujitsu Services shall provide Post Office with a copy of every Business Continuity Plan,
as and when created. Without prejudice to Fujitsu Services’ obligations in respect of the
Business Continuity Plans set out in this Schedule B2, the Business Continuity Plans shall
not be subject to Post Office approval.
Fujitsu Services shall ensure that the Business Continuity Plans for the Applicable
Services are compatible with the overall service continuity framework set out in the CCD
entitled “HNG-X Business Continuity Framework” (SVM/SDM/SIP/0001).
Ownership of all contingency actions shall be identified in the Business Continuity Plans.
Contingency actions to be undertaken by Post Office in the event a Business Continuity
Plan is activated, shall be agreed by the Parties before inclusion in that plan.
The Business Continuity Plans shall include activation procedures and time periods within
which the contingency measures shall be activated.
The testing strategy for Business Continuity Plans shall be in two distinct parts:
1.6.1 _ initial testing before commencing the implementation of new services introduced
under the Change Control Procedure; and
1.6.2 regular testing of relevant Service components.
The Business Continuity Plans, the scheduling of regular tests and the review of such
tests shall be subject to joint periodic review (at least four times per year) by the Business
Continuity Managers, the findings of such reviews to be reported to the Service
Management Relationship.
When a contingency or continuity operation is invoked as a result of a fault in the
Applicable Services provided by Fujitsu Services, then the provisions of the relevant
Service Description(s) that are affected shall continue to apply.
Fujitsu Services shall co-operate with Post Office and provide such assistance as is
reasonably requested by Post Office for the purposes of business continuity and fail-over
testing of End to End Services (excluding the elements of End to End Services provided
by Fujitsu Services). In the event that such co-operation and assistance is requested by
Post Office, Post Office and Fujitsu Services shall agree the method of working and the
periods for, timing and frequency of such testing so as to minimise disruption and risks to
Schedule B2 Version 13.0
Page 2 of 4
POL00027933
POL00027933
CONFIDENTIAL
21
22)
3.1
41
the operation of the HNG-X Services and/or the HNG-X Service Infrastructure. Fujitsu
Services’ charges in respect of such co-operation and assistance (which shall be paid by
Post Office to Fujitsu Services) shall be calculated on a time and materials basis using
Fujitsu Services’ rates as set out in paragraph 10.4 of Schedule D1.
Fujitsu Services shall comply with its obligations (if any) set out under the section entitled
“Business Continuity" in the Service Descriptions.
PLAN UPDATES
Fujitsu Services shall update the CCD entitled “HNG-X Business Continuity Framework”
(SVM/SDM/SIP/0001)) to include any:
2.1.1 references to new Business Continuity Plans and/or tests necessary to reflect:
2.1.1.1 any new services introduced under the Change Control Procedure; and
2.1.1.2 changes to Applicable Services brought about as a result of the
introduction of new services,
and shall submit that updated CCD to Post Office (for agreement) by the
applicable date specified in the relevant project plan (if any) or otherwise agreed
between the Parties; and
2.1.2 changes to references to Business Continuity Plans and descriptions of tests (to
the level of detail required in the CCD entitled “HNG-X Business Continuity
Framework” (SVM/SDM/SIP/0001)) necessary to reflect changes to any
Applicable Service such updates to be submitted to Post Office at such times as
the changes take place.
All updates to the CCD entitled “HNG-X Business Continuity Framework”
(SVM/SDM/SIP/0001) submitted to Post Office in accordance with paragraph 2.1 are
subject to agreement by Post Office, such agreement not to be unreasonably withheld.
MISCELLANEOUS
In the event of any major business continuity incident (“MBCI"), and when agreed
necessary by Post Office and Fujitsu Services' Business Continuity Managers for
potential MBCls, Fujitsu Services shall provide a report according to the principles set out
in the Working Document entitled “Operational Level Agreement for Business Continuity
between Post Office Ltd and Fujitsu Services” (CON/NGN/005).
FAILOVER TO SUNGUARD SITE
Notwithstanding anything to the contrary in this Schedule B2 or the CCD entitled “HNG-
X Business Continuity Framework” (SVM/SDM/SIP/0001) until such time as:
4.1.1 fully operational standby systems have been installed by Post Office or its
contractors at the Sunguard Site; and
Schedule B2 Version 13.0
Page 3 of 4
POL00027933
POL00027933
POL00027933
POL00027933
CONFIDENTIAL
4.1.2 Fujitsu Services' access to those systems has been established and tested,
there will be no fail-over capability to the Sunguard Site required for the links between the
Data Centres and the EDG at the Huthwaite site in the event of failure of those links or
the Huthwaite site.
5. Paragraph removed by CCN1610
5.1 Not Used
5.2 Not Used
5.3 Not Used
6. ASSOCIATED DOCUMENTS
6.1 The following CCDs are associated with this Schedule B2:
Document Reference Document Title
1 SVM/SDM/SIP/0001 HNG-X Business Continuity Framework
2 Not Used Not Used
3 Withdrawn in CCN1616b
4 Not Used Not Used
6.2 There are no CRDs associated with this Schedule B2.